ZL-37
Level 4 Post Emulsifiable Fluorescent Penetrant
Essential for critical component applications, ultra-high sensitivity ZL-37 post-emulsifiable penetrant is designed for detecting fine, tight discontinuities in safety-critical components, such as titanium turbine components, and in high-stress parts, such as investment castings.
This Type 1 penetrant is non-water-soluble so there is minimal risk of washing ZL-37 penetrant from a fine or shallow defect which makes this penetrant inspection the most reliable, dependable form of PT testing. ZL-37 has a high flash point and provides long tank life when used in open dip tanks, but this penetrant can also be applied in a variety of other ways, including electrostatic spray.
ZL-37 can be removed with ZE-4E Method B lipophilic emulsifier or ZR-10E Method D hydrophilic emulsifier.
ZL-37 is listed on the QPL SAE AMS 2644 Qualified Product List and is approved for use by Pratt & Whitney.
Benefits
Improve indication detection in the most critical applications
- Creates the clearest, brightest indications for even the finest flaws due to very strong UV and thermal stability
- Highest fluorescent brightness of any Level 4 penetrant for high-contrast indications that are easy for inspectors to see – even when the indications are very small
- Indications stand out more since background fluorescence is minimized; emulsifiers only remove surface penetrant without the risk of over-washing
Maximize penetrant inspection process control
- Prevents over-washing since ZL-37 cannot be removed with water (unless combined with an emulsifier)
- Post Emulsifiable penetrant system is less susceptible to human error since only surface penetrant is removed in the final rinse stage
Wide range of inspections
Features
- Level 4 ultra-high sensitivity
- Post emulsifiable
- Bright, high-contrast indications
- Resists over-washing or over-removal
- High flash point
- Wide range of application methods
- Low odor
- Very low toxicity
- Alloy compatibility
- Very high thermal resistance
- Very high UV stability
- High dye content
- QPL SAE AMS 2644 Qualified Product List
- Approved for use by Pratt & Whitney
NDT Type: Fluorescent Penetrant Testing
Penetrant Type: Type 1
Fluorescent Penetrant Sensitivity: Level 4 - Ultra-High Sensitivity
Penetrant Methods: Method B, Method C
Removal Type: Post Emulsifiable
Required Equipment: UV light source
Ideal Application: Aluminum, Detecting fine to very-fine discontinuities, Electrostatic spray, Finding wide, shallow flaws, High-stress parts, Immersion dip tank, Investment castings, Non-porous surfaces, Precision components, Safety-critical components, Smooth, machined surface finish, Titanium, Turbine engine blades, disks, etc.
Defect Examples: Finished surface cracks, Porosity, Scratches, Seams
Standards: AECL, AMS 2644, ASME BPVC, ASTM E1417, Boeing BAC 5423 PSD 6-46 or 8-4, Boeing PS-21202, ISO 3452, NAVSEA T9074-AS-GIB-010/271, Pratt & Whitney PMC 4354, QPL SAE AMS 2644